alert rules
A rule defines what PosKit watches, at what threshold, and on which devices or sites. Rules live on the alert rules page, reached from alerts.

the rules list
The Create Alert Rule button only appears if you hold alert:configure.
Once you have at least one rule, a stats strip shows total rules, active rules, critical rules and alerts triggered.
| Column | Contains |
|---|---|
| Rule | Severity icon, name, description, and tag badges |
| Category | The rule's category |
| Severity | Info, Warning or Critical |
| Assignments | "N devices/locations", or "Not assigned" |
| Actions | "N actions", or "No actions" |
| Status | An inline switch that enables or disables the rule |
Clicking a rule's name opens its detail page: a configuration summary, the devices currently at risk of breaching it, its recent triggers, plus Test and Edit buttons.
The row menu offers Edit Rule, Manage Assignments, Configure Actions, Test Rule and Delete Rule. The first three all open the same rule editor, landing on the matching tab.
Test Rule evaluates the rule immediately and reports either "Rule triggered" or that it did not trigger.
Delete Rule permanently deletes the rule, along with its actions, assignments and conditions. There is no undo.
Alerts already raised by the rule are kept. They are not deleted with it — they simply lose their association with the rule, so they no longer show which rule produced them and can no longer be filtered by it. The in-app confirmation dialog says associated alerts are deleted; that wording is wrong, and the alerts survive.
The toolbar has a search box covering name, description and tags, plus filters for Category, Severity and Status. With no rules yet, the page shows the empty state "Configure proactive alerting".
The Category filter offers All Categories, System, Application, Business, Network, Peripheral, Orders, Availability, SLA and Custom. Location-scope rules default to the Orders category.
creating a rule
Create Alert Rule opens a six-step wizard in a modal. Create with kit opens the same job as a conversation in the Kit drawer: describe the rule in a sentence ("cpu over 90% on the tills for 10 minutes") and the condition, duration and targets are filled in for you to confirm; naming a group that does not exist offers to create it first. The guided setup also starts on its own for an organisation that has no rules yet, for users with alert:configure. See guided setups.
Closing the modal discards the draft entirely. There is no save-as-draft and no recovery. If you are building a rule with a long assignment list, finish it in one sitting.
step 1 — alert area
Choose the scope. This is the most consequential choice in the wizard.
| Scope | Watches |
|---|---|
| device | Individual devices — cpu, disk, services, peripherals, printers, connectivity |
| location | Whole sites — order volumes and failure rates from connected order aggregators |
Switching scope wipes your template, conditions and assignments. Decide the scope before you build anything else.
step 2 — template
Offers "start from scratch" plus templates filtered to the scope you chose. Picking a template overwrites the name, category, severity and conditions.
Location templates
| Template | Condition | Severity |
|---|---|---|
| Order Failures | Failed orders ≥ 3 | Critical |
| Low Order Success Rate | Success rate < 90% | Warning |
| Site Offline | Devices online % ≤ 0 | Critical |
| Network Device Offline | Offline network devices ≥ 1 | Warning |
| Speedtest Variance | Variance > 20% | Warning |
Device templates
| Template | Condition | Severity |
|---|---|---|
| Device Offline | ≥ 5 minutes | — |
| Peripheral Error | > 0 | — |
| High Disk Usage | > 90 | — |
| High CPU Usage | > 80 | — |
| High Memory Usage | > 85 | — |
| High Temperature | > 70 | Critical |
| High Network Latency | > 200 | — |
| Service Down | — | Critical |
Templates are a faster and safer start than scratch, because they come with thresholds that are sane for a POS estate. Start from a template and adjust the thresholds to fit your estate — either in the wizard or later, in the rule editor.
step 3 — configure rule
| Field | Notes |
|---|---|
| Rule Name | Required |
| Description | Optional |
| Category | System, Application, Business, Network, Peripheral, Orders or Custom |
| Severity | Info, Warning or Critical |
| Conditions | At least one required |
Each condition is a metric, an operator and a threshold, with an Add Condition button for more.
With two or more conditions, a Trigger when control chooses how they combine: all conditions match (every condition must breach — the default) or any condition matches ("CPU high or memory high" is one rule). The same control appears when editing conditions on an existing rule. Nested groups mixing the two are not offered — that is two rules.
Operators are greater than, less than, equals, not equals, greater than or equal, and less than or equal.
Two families use different operators:
- Log-file and network-name conditions use Contains / Does not contain.
- Network device-type uses Is / Is not.
- Service status uses is / is not and a state, e.g. "Spooler is not running".
Every metric and its default threshold is listed in the metrics reference.
Advanced Settings at this step exposes exactly two fields:
| Field | Range | Default |
|---|---|---|
| Evaluation Interval (seconds) | 10–3600 | 60 |
| Cooldown Period (minutes) | 0–1440 | 5 |
Whatever you set as the Evaluation Interval, the engine only runs every 5 minutes. See how evaluation actually works.
step 4 — alert actions
The header says it directly: actions are optional — you can create alerts that only appear in the portal.
Quick Add offers Email Notification, Webhook, SMS, Run Script and Open Ticket.
| Action | Configuration |
|---|---|
| Recipients (comma-separated), optional Subject | |
| Webhook | URL, method (GET / POST / PUT) |
| SMS | Phone Numbers (comma-separated) |
| Run Script | Pick an automation script. On location-scope rules there is also a Target Device Tag — the script runs on the online device carrying that tag at the alerting location. Device rules always run the script on the alerting device |
| Ticket | Ticketing form |
Every action also has Execute On — When Triggered, When Resolved, or Both. See alert actions.
The rule editor's actions tab offers these five plus four more — Push Notification, Slack, Microsoft Teams and On-call Routing. See alert actions.
step 5 — smartfix
Requires the agentic-ai feature. Organisations without it see an upsell here instead.
| Setting | Notes |
|---|---|
| Enable SmartFix analysis | Master switch. SmartFix runs on every alert the rule raises, at any severity |
| Enable auto-remediation | Only available when analysis is on |
| Minimum Confidence Threshold % | 0–100, default 95. Only available when auto-remediation is on |
How far SmartFix may go to fix an alert is set by the organisation's SmartFix policy, not by these settings. Full detail is in smartfix.
step 6 — assignments
What the rule applies to.
| Scope | Targets available |
|---|---|
| Device | Device tags, location tags, device groups, specific devices |
| Location | Locations (with select all / clear all) and location tags |
The Create button stays disabled until at least one target exists. A rule with no assignments cannot be created.
Assign by tag or group rather than by picking individual devices. Tag-based assignment keeps working as the estate changes — a new till that registers with the right tags is covered immediately, with no rule edit.
editing a rule
Edit Rule opens a single tabbed editor with four tabs: conditions, assignments, actions and settings. Everything about a rule can be changed after creation.
the conditions tab
The conditions tab uses the same metric picker as the wizard: each condition is a metric, an operator and a threshold, with Add Condition for more, combined with AND.
Saving replaces the rule's existing conditions and resets its evaluation state — any consecutive-failure counters in progress start again from zero. Alerts the rule has already raised are unaffected.
the settings tab
Rule Name, Description, Category, Severity, Tags, the Enable switch, Evaluation Interval, Cooldown, and the SmartFix settings.
The settings tab's Category list also offers Availability and SLA, which the wizard does not. Tags (comma-separated free text) exist only here — the wizard has no tag field. To tag a rule, create it and then edit it.
settings you can only set by editing
These three are not in the wizard at all. Create the rule, then edit it.
| Setting | Range | Default | Effect |
|---|---|---|---|
| Consecutive Failures Required | 1–10 | 1 | A breach increments a counter; no alert fires until it reaches this number. A passing evaluation resets it |
| Repeat Interval (minutes) | 0–1440 | — | Re-notify on an open alert this often. 0 means no repeat |
| Escalate After (minutes) | 0–1440 | — | Raise severity and flag the alert escalated after this long unresolved. 0 means no escalation |
| Escalation Severity | — | — | The severity to escalate to |
Consecutive Failures Required is the single most effective noise control in the product. Setting it to 2 or 3 on a flappy metric such as network latency removes most transient spikes without raising your threshold and losing genuine sustained problems.
changing a threshold
Open the rule's editor, adjust the threshold on the conditions tab, save, then confirm the new behaviour with Test Rule. The rule keeps its identity: its alert history, assignments and actions are all untouched, and only its evaluation state resets.