Skip to main content

reconciliation

Device reconciliation compares Simphony configuration with PosKit infrastructure and shows you where the two disagree.

caution

Reconciliation needs an active CCAPI integration. See oracle simphony integrations.

what it surfaces​

Two kinds of discrepancy:

DiscrepancyMeans
Present in one system but not the otherA workstation Simphony knows about with no matching PosKit device, or a PosKit device with no matching workstation
Mismatched attributesBoth systems have the record, but details differ between them

results stream in​

note

Results arrive progressively rather than all at once. A partly-populated list is still being built — wait for it to settle before acting on what it shows.

how to use the output​

Reconciliation is a reporting tool: it tells you what disagrees, it does not resolve the disagreement for you. Typical follow-ups:

  • A workstation in Simphony with no PosKit device usually means the agent has not been installed on that machine, or it has never checked in. See installing the agent.
  • A PosKit device with no matching workstation may be decommissioned hardware still holding a record. See archiving before deciding.
  • Mismatched attributes are worth checking against the data browser to confirm which side is stale.
tip

Run reconciliation after any bulk change at a site — a refit, a workstation swap, or a round of agent installs. It is the fastest way to catch a machine that was replaced in Simphony but never registered with PosKit.